Vacuum Angle Valve-Pneumatically Actuated

GDQ series electric pneumatic high vacuum flapper angle valve is one of the important components in the vacuum system. It uses electrical signals as valve switch signals and relies on compressed air as the starting force for the valve plate to lift. When the power supply or compressed air is lost, the valve will automatically close by spring force. As the opening and closing mechanism in the high vacuum pipeline, this valve has the advantages of stable operation, reliable sealing, and long service life. It is one of the preferred valves for vacuum equipment automation. The valve is suitable for air or low-corrosive gas.
Specification size (DN): 16~50mm
Valve structure: normally open(NO); normally closed(NC)
Connection flange: KF
Leakage rate: 1x10⁻¹⁰Pa·m³/sec(1x10⁻⁹mbar·L/sec)
Drive mode: pneumatic
Drive air source pressure range: 3.5-8bar
Typical air source pressure: 6bar
Solenoid valve rated voltage: DC24V, AC220V (optional)
Shaft core sealing method: bellows seal or shaft seal
Body material: Al6063-T6, stainless steel (optional)
Seal ring material: FKM (fluororubber)
Installation method: Any
Heat resistance temperature: 150°C
Flow conductance: (4.5L/S-85L/S)
Service life: ≥500,000 times or cycles

Nominal voltage

 

DC voltage

24V

AC voltage

220v  (Optional)

Vacuum flange interface

KF16

KF25

KF40

KF50

Driver

Size of compressed air supply pipeline

Open: Pneumatic

Close: Spring

Pressure range

06mm  (Optional)

Cylinder exhaust volume

3.5~8x10pa

Valve stroke

3.3cm³

9.7cm³

35cm³

50cm³

Angle valve flow conductance

6.1mm

8.6mm

14.1mm

21.2mm

Switching frequency

5L/S

20L/S

50 L/S

85L/S

Opening time

<10/min

<10/min

<10/min

<10/min

Closing time

<0.2s

Service life

<0.2s

Vacuum leakage rate

≥500000

Maximum pressure value inside the valve

1x10⁻¹⁰pa-m³/sec  (1x10⁻⁹mbar-L/sec)

Minimum operating pressure inside the valve

5bar(absolute)

Maximum operating pressure inside the valve

1x10⁻⁸mbar

Pressure difference range

2bar

Closing direction

AP

Opening direction

≤5bar

Temperature

≤2bar

Working environment

 

Bake body

oC~50C

Cylinder

≤150C

Driver

150°C

Solenoid valve

150°C

Installation direction

20~70C

Flow direction

Any

Material

Any

Body

 

Valve body

 

Bellows assembly

Al6063-T6  (Green low-carbon hydropower photovoltaic aluminum)

Spring

SUS304/SUS316L

Seal ring

spring steel

Switch indicator box

F KM(fluororubber)

Visual position indicator

ABS/PC

Magnetic indicator (optional)

OMR ON Omron (lifespan over 30 million times)

Weight

DMS

Nominal voltage

0.35kg

0.78kg

1.62kg

1.96kg

×

Contact Us